"John Fergusson" <[EMAIL PROTECTED]> wrote:
> Do I have a config error?  If so where?

  Nope.  The Ascend binary attributes are *not* text.  Therefore, when
they're read from a DB and put into a RADIUS attribute, they may not
print in debug mode as exactly the same string as you put in the DB.

> If I query the output dirrectly from my sql I don't get the extra 0's
> being added.

  Exactly.  What you put into the DB is one thing.  What goes into the
packet (or printed in debug mode) is another.

  There's no problem.

  Alan DeKok.


- 