Hi,
I have a problem with the Filter-ID attribute :
When a switch (Enterasys) gets the filter-ID in an 'access-accept' reply,
its value is written twice :
.....
AVP: l=6 t=Service-Type(6): Framed-User(2)
AVP: l=39 t=Filter-ID(11): Enterasys:version=1:policy=test-policy
Filter-ID: Enterasys:version=1:policy=test-policy
AVP: l=39 t=Filter-ID(11): Enterasys:version=1:policy=test-policy
Filter-ID: Enterasys:version=1:policy=test-policy
AVP: l=58 t=Vendor-Specific(26) v=Microsoft(311)
AVP: l=58 t=Vendor-Specific(26) v=Microsoft(311)
AVP: l=6 t=EAP-Message(79) Last Segment [1]
.....
And this comportment confuses the switch (an old one).
This happens only in an EAP negociation. Not in clear Radius.
Do you know where this may come from ?
Something to do with the fact that I set "use_tunnelled_reply=yes" in
EAP.conf ?
Thanks in advance,
Vincent MAZARD
-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html