Few more details -
Controller / Cinder node:
Eth0 -> Private (VLAN 103), Public, Storage (VLAN 102), Management (VLAN 101)
Eth1 -> Admin (PXE)

Compute Node :
Eth0 -> Private (VLAN 103), Public, Storage (VLAN 102), Management (VLAN 101)
Eth1 -> Admin (PXE)

Note: our default VLAN (management) is 1.

Also, Kindly let us know which ports should be configured with access mode 
(with VLAN IDs) and which ports should be configured with trunk mode (with VLAN 
ids)

Thanks and Regards,
Gandhi Rajan

From: Gandhirajan Mariappan (CW)
Sent: Thursday, June 26, 2014 7:05 PM
To: [email protected]
Cc: 'Evgeniya Shumakher'; Andrey Danin; '[email protected]' 
([email protected]); Karthi Palaniappan (CW); Nataraj Mylsamy (CW); Harsha 
Ramamurthy; Prakash Kaligotla; Raghunath Mallina (CW)
Subject: Management IP of Compute is not reachable from Controller node and 
vice versa

Hi Fuel-Dev,

While deploying the slave nodes, we had below configuration in VCS device. Only 
if we have below configuration, deployment is getting successful and I can able 
to launch Horizon.

VCS Configuration - Access mode: - Used this configuration while deploying from 
Fuel UI
interface TenGigabitEthernet 133/0/7
fabric isl enable
fabric trunk enable
switchport
switchport mode access
switchport access vlan 1
spanning-tree shutdown
no shutdown
!
interface TenGigabitEthernet 133/0/13
fabric isl enable
fabric trunk enable
switchport
switchport mode access
switchport access vlan 1
spanning-tree shutdown
no shutdown
!
interface TenGigabitEthernet 133/0/21
fabric isl enable
fabric trunk enable
switchport
switchport mode access
switchport access vlan 1
spanning-tree shutdown
no shutdown
!

Now, we are not able to ping Compute node management ip (192.168.0.2) from 
Controller node (192.168.0.3) and vice versa.
Because of this "nova hypervisor-list" is empty. I tried configuring VCS device 
with above configuration (access mode) as well as below configuration (trunk 
mode).

When we are configuring trunk mode setting in VCS, both controller and compute 
nodes are going away from master node (we are getting notification in Fuel UI). 
Not sure what is the expected configuration.

Kindly let us know what should we do, so that "nova-hypervisor-list" will list 
compute node. I have attached diagnostic snapshot at 
https://www.dropbox.com/s/nf09krcx5zum371/fuel-snapshot-2014-06-26_13-19-07.tgz

VCS Configuration - Trunk mode:
interface TenGigabitEthernet 133/0/7
fabric isl enable
fabric trunk enable
switchport
switchport mode trunk
switchport trunk allowed vlan add 101-103
switchport trunk tag native-vlan
spanning-tree shutdown
no shutdown
interface TenGigabitEthernet 133/0/13
fabric isl enable
fabric trunk enable
switchport
switchport mode trunk
switchport trunk allowed vlan add 101-103
switchport trunk tag native-vlan
spanning-tree shutdown
no shutdown
interface TenGigabitEthernet 133/0/21
fabric isl enable
fabric trunk enable
switchport
switchport mode trunk
switchport trunk allowed vlan add 101-103
switchport trunk tag native-vlan
spanning-tree shutdown
no shutdown

Thanks and Regards,
Gandhi Rajan
-- 
Mailing list: https://launchpad.net/~fuel-dev
Post to     : [email protected]
Unsubscribe : https://launchpad.net/~fuel-dev
More help   : https://help.launchpad.net/ListHelp