Levente schrieb: >Klaus Rudolph <[EMAIL PROTECTED]> wrote: > > >>Hi all, >> >>I have a terrible problem which I could not solve :-( >> >>I have a set of circuits drawn with gschem. >>I use gsch2pcb to make the netlist and use it in pcb >> >>I allways get the following message: >>WARNING: Trying to rename something twice: >> PLUS5V and PLUS5V >>are both a src and dest name >>This warning is okay if you have multiple levels of hierarchy! >> >>As result my net PLUS5V is NOT connected to +5V and I could not route >>the circuit in pcb :-( >> >>Any hint to find the problem? >> >> > >I guess you have one net with two names. Or you have one net with two same >power symbol attached to it. > > I have three nets which use different names but should connected. This is Vcc because this is used in an avr symbol, then I use +5V from an other symbol (power) and then I have a net called PLUS5V. In one schematic I use 3 times output-2.sym with the attatched net=PLUS5V:1, net=Vcc:1 and so on. And normaly I want simply that these nets will be connected and whithout a warning :-)
> > >>If needed, I could send you my working directory as a tgz as pm, I don't >>want polute the list here :-) >> >> > >Could you upload somewhere, and send the link? > > Sorry, I have no web space :-( Bye Klaus _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user