On Sun, Mar 30, 2008 at 2:41 PM, Stefan Salewski <[EMAIL PROTECTED]> wrote: > Hello, > > there exists symbols with net attributes which are not > visible/accessible when symbol is inserted in a schematic, for example > > net=Vcc:14 > > Problem: I am using many different positive supply voltages, i.e. 5V and > 3.3V. I want that this symbol has 3.3V supply, but I have no Vcc defined > (or maybe Vcc is defined to be +5V). > > Can I simple add a new attribute to the symbol to overwrite the > invisible/hidden "net=Vcc:14" for pin 14 with something like "net= > +3.3V:14" ? > > I think that I have read that this overwriting of attributes shall work > -- but I can't find it again.
Why not just remove the hidden nets from the symbols? With mulitple values of Vcc (or GND) the hidden nets create a lot of hidden problems. (* jcl *) P.S. I have a script that removes the hidden nets and generates appropriate power symbols. -- http://www.luciani.org _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user