On Wednesday 30 April 2008 14:20:37 James Moody wrote: > My circuit design spans 2 sheets. To carry the signal from one to the > other I used the output and input flags, and added the attribute > "netname=CH A_1" to the output on one page and the corresponding input > on the other page. I did the same with "CH A_2", "CH B_1" and "CH B_2". > In the resulting netlist these nodes are unnamed, and the connection > between sheets was not made. I tried again after removing the space in > the value; no difference. >
Netname attributes should be attached to the net segments themselves. At the
moment, the input/output flags are only used for heirachy.
Cheers,
Peter
--
Peter Brett
Electronic Systems Engineer
Integral Informatics Ltd
signature.asc
Description: This is a digitally signed message part.
_______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user