I just went into each symbol in my schematic and changed the VDD:xx to Vcc:xx and VSS:xx to GND:xx. I then save the schematic and ran gsch2pcb and when I bring up the netlist it still has the VSS and VDD nets. It shouldn't because no symbol has those nets. I then went to quit the schematic and it showed a popup warning that 4 symbols have changed but I can't save them; it won't let me. Any suggestion?
On Mon, May 2, 2011 at 2:48 PM, Rob Butts <[1][email protected]> wrote: The symbols for the logic came from the 4000 series logic library in gshem. I'm glad I realized this because the design wouldn't have worked. On Mon, May 2, 2011 at 2:43 PM, DJ Delorie <[2][email protected]> wrote: If you have different symbols with different names for the same net, you'll have to rename them to all have the same net, yes. _______________________________________________ geda-user mailing list [3][email protected] [4]http://www.seul.org/cgi-bin/mailman/listinfo/geda-user References 1. mailto:[email protected] 2. mailto:[email protected] 3. mailto:[email protected] 4. http://www.seul.org/cgi-bin/mailman/listinfo/geda-user