> Quoting Roland Dreier <[EMAIL PROTECTED]>:
> Subject: Re: [PATCH] net/mlx4: modify sw reset
> 
> Thanks, I applied a version of this that checks the vendor field is !=
> 0xffff instead of checking it against the mellanox value, because
> someone may build HCAs with a different vendor value.
> 
> Also is it worth taking the semaphore in the mthca reset function?

Why not? PRM says we should - the point of this is protecting against someone
accidentally touching flash while device is reset,
which will result is hangs, system errors or even data corruption.

-- 
MST
_______________________________________________
general mailing list
[email protected]
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general

To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general

Reply via email to