Attention is currently required from: csaba.sipos, laforge. pespin has posted comments on this change by csaba.sipos. ( https://gerrit.osmocom.org/c/osmo-bsc/+/42289?usp=email )
Change subject: nokia_site: Change the LAPD N200 counter for RSL ...................................................................... Patch Set 5: (1 comment) Patchset: PS5: I'm not entierely following your rationale. So that timeout happens at LAPD level only when the TRX is being configured (ie. during osmo-bsc boot or BTS re-connect)? But at that time there's no MS attached yet so no LAPD issue? What am I missing or not understanding? -- To view, visit https://gerrit.osmocom.org/c/osmo-bsc/+/42289?usp=email To unsubscribe, or for help writing mail filters, visit https://gerrit.osmocom.org/settings?usp=email Gerrit-MessageType: comment Gerrit-Project: osmo-bsc Gerrit-Branch: master Gerrit-Change-Id: Ie4bb804ea636eba2182586db13a625c5933eff31 Gerrit-Change-Number: 42289 Gerrit-PatchSet: 5 Gerrit-Owner: csaba.sipos <[email protected]> Gerrit-Reviewer: Jenkins Builder Gerrit-Reviewer: fixeria <[email protected]> Gerrit-Reviewer: laforge <[email protected]> Gerrit-Reviewer: pespin <[email protected]> Gerrit-CC: domi <[email protected]> Gerrit-Attention: csaba.sipos <[email protected]> Gerrit-Attention: laforge <[email protected]> Gerrit-Comment-Date: Fri, 13 Mar 2026 11:43:02 +0000 Gerrit-HasComments: Yes Gerrit-Has-Labels: No