On 9/14/18 3:14 AM, Rakesh Mishra wrote:
Dear Dr. Justin,

Of course I agree with your points. There is no point to not believe on you,
that's why we are discussing and thanks for your comment.
I raised the question because I observed the problem .
And it was matter of just common sense for me that
why the change of saving frequency is affecting the much difference
in the maximum value of force curve in pulling along the axial direction.

Let me clear again, I say Input parameters of the pull.mdp files are same
for both the simulation.
Only difference is the different saving frequency of position and energy
coordinates.
Please see below two cases

Case -A

   simulation of same system with same input parameter during pulling
1  nstxtcout    = 2000       ; every 4 ps
     nstenergy    = 5000

2  nstxtcout    = 2000       ; every 4 ps
     nstenergy    = 2000

    (output files, pullf1.xvg, and pullf2.xvg are different very much w.r.t
peak value of force )
     Same thing happening also in the following below case, please see
this.

Case B.

1  nstxtcout    = 2000       ; every 4 ps
     nstenergy   = 5000

2-  nstxtcout    = 1000       ; every 4 ps
      nstenergy   = 5000

Because, now this gromacs discussion user platform do not allow to upload
any other data (eg, plot, pdf file etc) otherwise I can upload the plot.

You can always upload images to file-sharing services and provide links.

But first, watch the trajectories and see how they're behaving. The systems are likely just doing somewhat different things, as I said before. There is no reason to expect even the exact same .tpr file to produce the exact same output (binary identical), for reasons stated here: http://www.gromacs.org/Documentation/Terminology/Reproducibility

Again, I emphasize that output control has no impact on the computation of forces or anything to do with the pull code. This cannot be the reason for differences in trajectories.

-Justin

On Thu, Sep 13, 2018 at 4:57 PM, Justin Lemkul <jalem...@vt.edu> wrote:


On 9/13/18 1:20 AM, Rakesh Mishra wrote:

I do not believe .

Because if I run multiple simulation of pulling with the same system and
with the
same inputs then almost we are getting similar force/time curve.
While we are getting different curve if we are saving position coordinates
or energy
coordinates with different frequency.

There is no aspect of the code in which the computation of forces depends
on output frequency. You're welcome to disbelieve me, but you're clearly
just getting different simulation outcomes from different inputs, or
there's something else that differs that you haven't realized or haven't
told us.

-Justin


On Wed, Sep 12, 2018 at 8:15 PM, Justin Lemkul <jalem...@vt.edu> wrote:

On 9/12/18 8:42 AM, Rakesh Mishra wrote:

Dear Justin
It is totally surprised for me.
    I am pulling the same system of bdna
with the same constant velocity (0.005nm/ps).

Case 1
let for first case, When I am saving position coordinate (nstxtc ) in
the
interval of 4ps
and saving energy coordinate in the interval of 4ps.

Case 2
In the second case of pulling of the same system with the same velocity,
we
save position
coordinate in the interval of 4ps but we save energy coordinate in the
interval of  10ps.

Now in the output file of force.xvg for both case qualitative behaviour
of
diagram is same but
Peak of the forces are much differ.  Why this saving frequency is
affecting
the peak value. While
it is just saving the coordinates.

We also found that, if we save energy coordinate with the same frequency
and position
coordinate with different frequency then, again peak value of forces are
different.
Which should not. Why it is happening. Can you clarify please.

Your results have nothing to do with the save frequency. The output in
pullf.xvg is specified by pull-nstfout, not any of the others. You have
different simulations that behave differently, because there are elements
of randomness in any MD simulation. Pulling is a non-equilibrium process;
you may have to run several times with different pull vectors to find the
minimum-energy path.

-Justin



On Thu, Sep 6, 2018 at 5:20 PM, Justin Lemkul <jalem...@vt.edu> wrote:

On 9/6/18 2:29 AM, Rakesh Mishra wrote:
While I have purely physics background.

But, In my thinking, there are hydrogen bonds (electrostatic
attractive
interaction)
between bp of  both the strands of DNA/RNA  which are perpendicular to
helix direction.
And the other thing you have chosen very fast velocity like (0.01,
0.001,
0.005 ).
This can also be the reason of smoothness. But can you tell me one
thing
please,the
value of spring constant of biasing that you have taken (k= 1000), is
standard or not . If this value can be taken for peptide pulling .
Can
this value of
spring constant (k=1000) can be taken  for DNA (or dna+drug) pulling
or
not .

There is no such thing as a "standard" force cons
<https://maps.google.com/?q=no+such+thing+as+a+%22standard%22+force+cons&entry=gmail&source=g>tant
for pulling.

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Assistant Professor
Virginia Tech Department of Biochemistry

303 Engel Hall
340 West Campus Dr.
Blacksburg, VA 24061

jalem...@vt.edu | (540) 231-3129
http://www.thelemkullab.com

==================================================

--
Gromacs Users mailing list

* Please search the archive at http://www.gromacs.org/Support
/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
send a mail to gmx-users-requ...@gromacs.org.



--
==================================================

Justin A. Lemkul, Ph.D.
Assistant Professor
Virginia Tech Department of Biochemistry

303 Engel Hall
340 West Campus Dr.
Blacksburg, VA 24061

jalem...@vt.edu | (540) 231-3129
http://www.thelemkullab.com

==================================================

--
Gromacs Users mailing list

* Please search the archive at http://www.gromacs.org/Support
/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
send a mail to gmx-users-requ...@gromacs.org.



--
==================================================

Justin A. Lemkul, Ph.D.
Assistant Professor
Virginia Tech Department of Biochemistry

303 Engel Hall
340 West Campus Dr.
Blacksburg, VA 24061

jalem...@vt.edu | (540) 231-3129
http://www.thelemkullab.com

==================================================

--
Gromacs Users mailing list

* Please search the archive at http://www.gromacs.org/Support
/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
send a mail to gmx-users-requ...@gromacs.org.




--
==================================================

Justin A. Lemkul, Ph.D.
Assistant Professor
Virginia Tech Department of Biochemistry

303 Engel Hall
340 West Campus Dr.
Blacksburg, VA 24061

jalem...@vt.edu | (540) 231-3129
http://www.thelemkullab.com

==================================================

--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

Reply via email to