Dear all,

i think i found a bug in GSASII. I try to make a sequential refinement on up to 300 datasets. And I want all the datasets to have the same sample parameters. So i set the right sample parameters for the first dataset (which is with Debye-Scherrer as diffractometer type). Then i press copy->set all->Ok. So it turns out that everything is copied to the other datasets but not the Diffractometer type which still reads Bragg-Brentano (which is the default one). I dont really want to go through 300+ datasets all the time to set it to the right type. Does anyone else experience this error? I am currently working on a linux machine, maybe thats the problem. I am thankful for any help or work-around.

Best regards,
Lukas Grossmann

--
Dr. Lukas Grossmann

Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM II)
Technische Universität München
Arbeitsgruppe Advanced Materials

Lichtenbergstr. 1
85748 Garching

Raum UYW05 42
Tel: +49 (0)89 289 54725
Mob: +49 (0)178 197 5707

_______________________________________________
GSAS-II mailing list
[email protected]
https://mailman.aps.anl.gov/mailman/listinfo/gsas-ii

Reply via email to