Hello, I am using the preprocessed data of resting state MEG signal, in the Matlab matrix the data is divided into 2 seconds, then for the work I am dealing with right now we need around 10 seconds of the data, 5 trials , thus the data is redefined to 10 seconds, and as we expect there is no discontinuity on electrode level , BUT when I compute the inverse problem by sLoretta the time series of each source has that exact 5 times discontinuity, so I checked the result for different number of trials and this happened again? so as it is so odd to me, I would like to know your opinion about it and how can I solve it? Thanks
_______________________________________________ HCP-Users mailing list [email protected] http://lists.humanconnectome.org/mailman/listinfo/hcp-users