> > > - the CP detector works, but you somehow didn't provid the necessary > > commands (-> this can be set up in the preferences). Which arguments > > does hugin use as a default for this CP detector? (Look this up in > > 'Preferences' -> 'CP detectors' where you can choose the 'default' > > setting and click the 'edit' button) > > --maxmatches %p --projection %f,%v %o %i > Remove the --projection %f,%v switch from the arguments. It is a known bug that certain version of autopano-sift-c have problems with this parameters. Use instead --maxmatches %p %o %i
-- You received this message because you are subscribed to the Google Groups "Hugin and other free panoramic software" group. A list of frequently asked questions is available at: http://wiki.panotools.org/Hugin_FAQ To post to this group, send email to [email protected] To unsubscribe from this group, send email to [email protected] For more options, visit this group at http://groups.google.com/group/hugin-ptx