And if you dont know which ASID to stop, WLM will shutdown and restart all
WLM inits if you issue:

$PXEQ
$SXEQ

The $PXEQ will make all active WLM INITS shutdown when their batch work
terminates.
The $SXEQ will let any new work start in new INITS.

On Wed, 25 May 2005 22:15:34 -0700, Gerhard Adam <[EMAIL PROTECTED]>
wrote:

>>
>>> You should be able to simply stop the initiator with P INIT,ASID=xx ..
>>> then WLM will restart with a fresh initiator
>>
>>
>> P INIT,ASID=006C
>> IEE535I STOP     INVALID PARAMETER
>>
>OK .. my mistake.  The syntax is P INIT,A=xx
>


Regards
Bruce Hewson

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to