Hi,
Here are the messages from D M=CHP(B0,B8)
D M=CHP(B0,B8)
IEE174I 09.08.40 DISPLAY M 942
CHPID B0: TYPE=03, DESC=ESCON POINT TO POINT, ONLINE
CHPID B8: TYPE=04, DESC=ESCON SWITCHED OR POINT TO POINT, ONLINE
DEVICE STATUS FOR CHANNEL PATH B0
0 1 2 3 4 5 6 7 8 9 A B C D E F
040 . . . . + + + + . . . . . . . .
SWITCH DEVICE NUMBER = NONE
PHYSICAL CHANNEL ID = 0165
************************ SYMBOL EXPLANATIONS ************************
+ ONLINE � PATH NOT VALIDATED - OFFLINE . DOES NOT EXIST
* PHYSICALLY ONLINE $ PATH NOT OPERATIONAL
DEVICE STATUS FOR CHANNEL PATH B8
0 1 2 3 4 5 6 7 8 9 A B C D E F
040 . . . . $ $ $ $ . . . . . . . .
SWITCH DEVICE NUMBER = NONE
PHYSICAL CHANNEL ID = 0176
************************ SYMBOL EXPLANATIONS ************************
+ ONLINE � PATH NOT VALIDATED - OFFLINE . DOES NOT EXIST
* PHYSICALLY ONLINE $ PATH NOT OPERATIONAL
When putting the CHP online I get:
CF CHP(B8),ONLINE
IOS444I DYNAMIC PATHING NOT OPERATIONAL ON PATH (0406,B8)
IOS444I DYNAMIC PATHING NOT OPERATIONAL ON PATH (0405,B8)
IOS444I DYNAMIC PATHING NOT OPERATIONAL ON PATH (0407,B8)
IOS444I DYNAMIC PATHING NOT OPERATIONAL ON PATH (0404,B8)
IEE754I NOT ALL PATHS BROUGHT ONLINE WITH CHP(B8)
IEE502I CHP(B8),ONLINE
IEE712I CONFIG PROCESSING COMPLETE
When displaying the Unit connected to the CHP:
DEVICE 0404 STATUS=ONLINE
CHP B8 B9 B0
DEST LINK ADDRESS 0D 0D 0D
ENTRY LINK ADDRESS .. .. ..
PATH ONLINE N N Y
CHP PHYSICALLY ONLINE Y Y Y
PATH OPERATIONAL N N Y
MANAGED N N N
MAXIMUM MANAGED CHPID(S) ALLOWED: 0
DESTINATION CU LOGICAL ADDRESS = 00
It is not connected to a switch!
I deleted B8 and added it again but got same results!
Hope this helps, thanks.
Ottar
----------------------------------------------------------------------