All, we have a problem that just reared its ugly head the other night.
It happened again last night. (different volume than the previous night)
We do a display unit on one of our LPAR's and get the following:

 

First LPAR

 

D,U,,,3169,2

IEE457I 14.39.08 UNIT STATUS 291

UNIT TYPE STATUS        VOLSER     VOLSTATE

3169 3390 A               O&04     PRIV/RSDNT

316A 3390 A             TEST74     PRIV/RSDNT

 

Performing the display unit on our second LPAR we get:

 

Second LPAR

 

D,U,,,3169,2

IEE457I 14.39.48 UNIT STATUS 259

UNIT TYPE STATUS        VOLSER     VOLSTATE

3169 3390 O             TTOP04     PRIV/RSDNT

316A 3390 O             TEST74     PRIV/RSDNT

 

Subsequently, there were batch jobs that received the following error
caused by the bizarre volser on our first LPAR.

 

IGD17264I VOLUME,(TTOP04),AND UCB DO NOT MATCH FOR DATA SET

 

How could the volser get messed up on one LPAR like that? TTOP04 is the
correct volser but the first LPAR doesn't indicate that. Anyone seen
this before?

 

 

Bill Johnson

Systems Programmer

Antares Management Solutions

23700 Commerce Park Rd.

Beachwood, Ohio 44122

216-292-0400 x3478

[EMAIL PROTECTED]
<mailto:[EMAIL PROTECTED]> 

 


------------------------------------------------------------------------------
CONFIDENTIALITY  NOTICE:   This message is  intended only for the use of
the  individual or  entity to  which it is  addressed  and  may  contain
information  that is privileged,  confidential or exempt from disclosure
by law.  If the reader of this message is not the intended recipient, or
the  employee  or agent responsible  for delivering  the message  to the
intended  recipient,  you  are  hereby  notified that  you are  strictly
prohibited  from   printing,  storing,  disseminating,  distributing  or
copying  this message.   If you have  received  this message  in  error,
please notify us immediately  by replying to the message and deleting it
from your computer.   Neither this information block,  the typed name of
the sender,  nor anything else in this message is intended to constitute
an electronic signature,  unless a specific statement to the contrary is
included in this message.  Thank you, Antares Management Solutions.
==============================================================================

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to