Hi Ted, Bill, Peter, Re. > ... > Now just to find out what causes the MIH to be raised... > ... > > Usually, shared DASD with many images that are not converting reserves to ENQ's. > Either by GRS or CA-MIM. > > Not 100%. But, common. >
We are a merger. And we have HSMs with CDSQ=YES & CDSR=YES serialization and without any CDSQ & CDSR specification. According to the 1994 HSM apar OY40882 (about RESERVE and GLOBAL ENQ INTERLOCKing...), CDSQ=YES & CDSR=YES works with GRS/MII serialization while CDSQ & CDSR being not specified works with RESERVE. So I'll have the HSM guys look into this. It looks to me as if the HSMs themselves are negatively impacting each other, the only data set on the voilume being the OCDS with it's VVDS, VTOCINDEX & VTOC. Thanks for all your help & fingerpointing! JAn ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html

