Howard Rifkind wrote:

In the process of upgrading SMP/E to V3R3 the apply check ran without any 
issues, RC=0.

Running the apply it blasted the day lights out of things starting with a 
failure on a GIM dataset which ran out of directory blocks.

What would be the best way to back things out to prior to running the apply 
step.

Simply rename the too-small library, allocate a new, larger version and copy the entire contents using IEBCOPY (use COPYMOD for modules). Then re-run the APPLY.

--
-----------------------------------------------------------------
| Edward E. Jaffe                |                                |
| Mgr, Research & Development    | [EMAIL PROTECTED]    |
| Phoenix Software International | Tel: (310) 338-0400 x318       |
| 5200 W Century Blvd, Suite 800 | Fax: (310) 338-0801            |
| Los Angeles, CA 90045          | http://www.phoenixsoftware.com |
-----------------------------------------------------------------

----------------------------------------------------------------------