In a message dated 7/29/2005 1:31:49 P.M. Central Daylight Time,  
[EMAIL PROTECTED] writes:
 
>Actually I think a WRITE DATA CCW with a 
>zero data length would  cause an error.

 
The 2105 does not specifically say that either a Write Data or a Write  Key 
and Data with a 0 length in the CCW byte count will cause an error if  inside a 
Locate Record Domain, so I think they would work there,  but they will cause 
a Unit Exception error outside a Locate Record  Domain.

>An EOF can have a key and you could then do an update write (WRITE  
>KEY/DATA CCW) to change the key, but no access method or program I know  
>of supports a key on an EOF.



The control unit supports this bizarre combination on a formatting  write.
 
 
Bill Fairchild

----------------------------------------------------------------------