Thanks everyone for the input , this is what I tried from HSM Admin Guide :
//STEP1 EXEC PGM=IEBGENER
//SYSPRINT DD SYSOUT=*
//SYSUT1 DD DUMMY,LRECL=16384,BLKSIZE=16384,RECFM=F
//SYSUT2 DD DSN=DFHSM.HMIGTAPE.DATASET,
// DISP=(NEW,KEEP),DCB=*.SYSUT1,UNIT=TAPE3590,
// VOL=SER=H00033 <<< -- Damaged Tape
//SYSIN DD DUMMY
/*
But again it somehow ending with this error :
*IEF233A M 6500,H00033,,LSP0RBH1,STEP1,DFHSM.HMIGTAPE.DATASET
IOS000I 6500,45,IOE,02,0600,,**,,LSP0RBH1 698
004914D050205451 0202FF1400003037 0000000000000190 41042300BEFD1312
UNSUPPORTED FORMAT
IEC512I LBL ERR 6500,
,NL,H00033,SL,LSP0RBH1,STEP1,DFHSM.HMIGTAPE.DATAS
EDG4031I VOLUME NL REJECTED. THE CREATION OF STANDARD LABELS IS NOT
PERMITTED
EDG4006E VOLUME NL ON 6500 REJECTED FOR USE BY LSP0RBH1, STEP1, OPEN
REQUEST FAILED BY DFSMSrmm IEC145I
413-08,IFG0194K,LSP0RBH1,STEP1,SYSUT2,6500,,DFHSM.HMIGTAPE.DATASET
IEA995I SYMPTOM DUMP OUTPUT 704
SYSTEM COMPLETION CODE=413 REASON CODE=00000008
TIME=15.34.23 SEQ=05369 CPU=0000 ASID=0206
PSW AT TIME OF ERROR 075C1000 80DB58FE ILC 2 INTC 0D
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW 00DB58F8 - 41003B62 0A0D41F0 38A656F0
GR 0: 00DB5BC4 1: A4413000
2: 00008CC0 3: 00DB5062
4: 009D0410 5: 009D07A4
6: 009D074C 7: 009D07A4
8: 009D076C 9: 009D1960
A: 009D1969 B: 00DB7B04
C: 80DB7BE4 D: 009D06D0
E: 80DB519A F: 00000008
END OF SYMPTOM DUMP
IEF450I LSP0RBH1 STEP1 - ABEND=S413 U0000 REASON=00000008 706
Any suggestions ?
On Wed, Aug 5, 2009 at 12:49 AM, Neal Scheffler <[email protected]> wrote:
> The procedure to write a new label on an ML2 volume is covered in the
> DFSMShsm Storage Administration Guide under chapter 20 Data Recovery
> Scenarios.
>
> Neal Scheffler
>
> ROHIT wrote:
>
>> Hell Guys ,
>>
>> We unfortunatley ended up having a 3590 ML2 tape which is giving NO LABEL
>> error and 6000 datasets sitting on it are unreadable, tape ops confirmed
>> that its not being identified by the drives .
>>
>> IOS000I 6503,B3,IOE,02,0600,,**,,DFHSM 468
>> 004914D050205451 0202FF1400003037 0000000000000190 41042300BEFD1312
>> UNSUPPORTED FORMAT
>> IEC512I I/O ERR 6503, ,NL,DFHSM,DFHSM,DFHSM.HMIGTAPE.DATASET
>> IEC502E R 6503,, ,NL,DFHSM,DFHSM
>> IEC501A M 6503,H00033,SL,,DFHSM,DFHSM,DFHSM.HMIGTAPE.DATASET
>>
>> Tried recycling but again not helping because its not getting identified
>> by
>> system.
>>
>> Can any one advise how to define a new label or any other resoultion ,
>> appreciate your input .
>>
>>
>> Thanks in Advance ,
>>
>> Rohit
>> IBM
>>
>> ----------------------------------------------------------------------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to [email protected] with the message: GET IBM-MAIN INFO
>> Search the archives at http://bama.ua.edu/archives/ibm-main.html
>>
>>
>>
>>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
>
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html