And the data set name does not have to be a real data set.  E.g., 
DSN=MY.BOGUS.DATA.SET.NAME.ETC.ETC.ETC.98765432

Bill Fairchild

Software Developer 
Rocket Software
275 Grove Street * Newton, MA 02466-2272 * USA
Tel: +1.617.614.4503 * Mobile: +1.508.341.1715
Email: [email protected] 
Web: www.rocketsoftware.com


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of 
Walt Farrell
Sent: Wednesday, August 05, 2009 10:07 AM
To: [email protected]
Subject: Re: 2 Identical STC Running at the Same Time

You could put in a DD statement referencing some dsname with DISP=OLD.  That
would prevent a second STC using that same dsname from running.

-- 
Walt

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to