> -----Original Message-----
> From: IBM Mainframe Discussion List 
> [mailto:[email protected]] On Behalf Of Ted MacNEIL
> Sent: Wednesday, August 05, 2009 12:01 PM
> To: [email protected]
> Subject: Re: 2 Identical STC Running at the Same Time
> 
> >As long as the DD is never opened, the VTOC is never 
> searched for the DSN.
> 
> What is special about this?
> I've always received JCL errors when specifying DISP=OLD with 
> a non-existant DSN.
> And, I started in this business as a JCL jockey (Production 
> Support) in February 1981.
> 
> Is it the VOL=REF?
> 
> -
> Too busy driving to stop for gas!

Yes, it is the VOL=REF, or a VOL=SER, which makes it work. In both cases, the 
parameter causes the initiator to bypass the catalog lookup of the DSN=. Of 
course, then DSN in the VOL=REF= must be catalogued on DASD!

--
John McKown 
Systems Engineer IV
IT

Administrative Services Group

HealthMarkets(r)

9151 Boulevard 26 * N. Richland Hills * TX 76010
(817) 255-3225 phone * (817)-961-6183 cell
[email protected] * www.HealthMarkets.com

Confidentiality Notice: This e-mail message may contain confidential or 
proprietary information. If you are not the intended recipient, please contact 
the sender by reply e-mail and destroy all copies of the original message. 
HealthMarkets(r) is the brand name for products underwritten and issued by the 
insurance subsidiaries of HealthMarkets, Inc. -The Chesapeake Life Insurance 
Company(r), Mid-West National Life Insurance Company of TennesseeSM and The 
MEGA Life and Health Insurance Company.SM

 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to