>>Is it possible to isolate one LPAR in a CEC and set the date/time to a
>>different value than the other LPARs in the same CEC?


>Yes.  This has been possible since the 9672 G5 (I think... could
>have been prior).  This was needed for Y2K testing.  Of course
>you have to have your CLOCKxx member set up to not use
>the sysplex timer.

>Search the archives or google for Y2K and TOD.

You can set a logical partition time offset via the LPAR image
profile. This can be done regardless of whether the CEC is in
LOCAL (unsynchronized), ETR or STP timing mode.

Regards,
George Kozakos
z/OS Software Service, Level 2 Supervisor

----------------------------------------------------------------------