John,

Thanks, for bringing this up.  Here is a screenshot from ISMF:

CDS Name  . : ACTIVE                                                  
CDS Status  : VALID                                                   
                                                                      
Description : PRODUCTION SYSTEMS BASE CONFIGURATION                   
==> . . . . :                                                         
Default Management Class :             Default Device Geometry :      
Default Unit . . . . . . : DISK          Bytes/track . . . . . : 56664
                                         Tracks/cylinder . . . : 15   
DS Separation Profile :                                               
System: TOL2                                                          
                                                                      
                                                                      
                                                                      
Sysgrp: CINPLEX  CINTPLEX           



Yes, we do specify sysgrp.  So the production plex is CINPLEX and has
99.9% of the DASD ownership, CINTPLEX is my sometimes up testing
sysplex.  CINPLEX would be the name that changes to something else.  So
are you saying if I added "newPLEX" to the SYSGRP list, then I
would/should be good?  No, volume conversions necessary?

And of course, I would assume that if we are doing any IF/THEN/ELSE
logic in the ACS routines with SYSGRP name, we would also have to
account for that(not sure there is, I'm not the storage team)?

_________________________________________________________________
Dave Jousma
Assistant Vice President, Mainframe Services
[email protected]
1830 East Paris, Grand Rapids, MI  49546 MD RSCB1G
p 616.653.8429
f 616.653.8497

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of John Kington
Sent: Wednesday, November 25, 2009 8:33 AM
To: [email protected]
Subject: Re: Changing SYSPLEX name

David
Regards,
John
513-723-7527
[email protected]

>But, I still have this nagging idea in my head though that SMS
>controlled volumes have sysplex name on them somewhere.  

Are you using system (names) or system group(s) in your SMS
configuration? Your system group name needs to match the SYSPLEX name.


This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to