Sorry I lost track of most of the interim suggestions toward this thread.
Did anyone suggest using a PDSE as the target library?  Years ago I cobbled
together a poor man's scheduling system that used a single PDSE as a
repository of members that each nightly batch job would add, as they
completed with CC<5.  Hundreds of jobs updated this PDSE over the course of
the evening, resulting in thousands of members having been written. .

Sorry if I've restated someone else's post.



  

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Frank Swarbrick
Sent: Thursday, December 03, 2009 5:34 PM
To: [email protected]
Subject: Re: IEC143I 213-30

>>> On 12/3/2009 at 6:39 AM, in message
<[email protected]>, "Shmuel Metz (Seymour J.)"
<[email protected]> wrote:
> In <[email protected]>, on 12/02/2009
>    at 12:51 PM, Frank Swarbrick <[email protected]> said:
> 
>>So perhaps a combination of the two is in order.  Write to a temporary 
>>PDS during the translate and then use DISP=OLD on the copy from the 
>>temp PDS in to the actual PDS.
> 
> The Initiator does the DISP=OLD ENQ at the beginning of the job. 

So you are saying that there is no point doing the two step process I
mention because it will have the file enqueued for the life of the job no
matter what, if DISP=OLD is specified?  Hmm, oh well.  Thanks for the info.
-- 

Frank Swarbrick
Applications Architect - Mainframe Applications Development FirstBank Data
Corporation - Lakewood, CO  USA
P: 303-235-1403




The information contained in this electronic communication and any document
attached hereto or transmitted herewith is confidential and intended for the
exclusive use of the individual or entity named above.  If the reader of
this message is not the intended recipient or the employee or agent
responsible for delivering it to the intended recipient, you are hereby
notified that any examination, use, dissemination, distribution or copying
of this communication or any part thereof is strictly prohibited.  If you
have received this communication in error, please immediately notify the
sender by reply e-mail and destroy this communication.  Thank you.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: GET IBM-MAIN INFO Search the
archives at http://bama.ua.edu/archives/ibm-main.html

_______________________________________
No viruses found in this incoming message Scanned by iolo AntiVirus 1.5.8.3
http://www.iolo.com

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to