Bob,
Try the following, changing CPC SNA to your particular configuration, note this 
is READ access only, change to your taste:

RDEFINE FACILITY HWI.APPLNAME.HWISERV UACC(NONE)  
                                                  
RDEFINE FACILITY HWI.TARGET.IBM390PS.xxxx         
       UACC(NONE) APPLDATA('BCPII')               
                                                  
PERMIT HWI.APPLNAME.HWISERV                       
       CLASS(FACILITY) ID(userid) ACCESS(READ)    
                                                  
TSS PERMIT HWI.TARGET.IBM390PS.xxxx               
       CLASS(FACILITY) ID(userid) ACCESS(READ)    
                                                  
TSS PERMIT HWI.TARGET.IBM390PS.xxxx.*             
       CLASS(FACILITY) ID(userid) ACCESS(READ)    

Thanks and regards,

Krzysztof (Chris) Bytnerowicz 
CA Technologies
Senior Software Engineer 
Sydney Development Lab
Tel:  +61 2 88982673 
Fax: +61 2 9429 2394 
mailto:[email protected] 

----------------------------------------------------------------------