Chris,

  Check your SMS CDS Base Display - Option 7.1.

For 3390s it should read Default Device Geometry :      
  Bytes/track . . . . . : 56664
  Tracks/cylinder . . . : 15   

If it reads Bytes/track 48K, SMS will adjust the allocation required.

Thank You,
Dave O'Brien
NIH Contractor
________________________________________
From: Chris Burgess [[email protected]]
Sent: Tuesday, September 28, 2010 11:38 AM
To: [email protected]
Subject: RRDS on SMS Managed Volume

I am having an issue trying to use RRDS data sets on SMS managed volumes. I
was using an IO generator that was creating 11 cylinder data sets on the
volume. It was getting an IEC070I 209-220. The same job worked fine on a
non-SMS volume. I did further testing where I would use IDCAMS to define and
load records via REPRO to the file. On the SMS managed volume, I had to
specify CYLINDERS(13 0) to get 11 cylinders allocated. This was not true on
the non-SMS managed volume. Can anyone provide some insight as to why SMS
needs the extra two cylinders? Any help would be greatly appreciated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html