> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of Rob Scott
> 
> John,
> 
> >> Why can't SMP/E do the ICKDSF PUTIPL command as well? It should
know the volser to update - it is
> the one containing the updated SYS1.NUCLEUS.
> 
> Surely most sites do not IPL their system from the SMP/E volumes and
datasets - there is normally some
> sort of propagation JCL to copy to "real" runtime SYSRES volumes - and
as stated previously there is
> no harm to suffix that copy JCL with a PUTIPL.

I can't speak for "most shops", but we IPL the "sandbox" from the SMP/E
target volumes after a maintenance APPLY or z/OS upgrade.  After a
suitable time to verify everything, THEN we "clone" the target volumes
to the other LPARs' respective "alternate" RES sets and IPL from those
"alternates" in turn; then "clone" the SMP/E target volumes to the
sandbox "primary" set and IPL the sandbox from "primary".  Now we're
ready for the next "cycle".

   -jc-

----------------------------------------------------------------------