Show your IXCL1DSU  input.

On Mon, 27 Dec 2010 16:35:00 +0800 ibmnew <[email protected]> wrote:

:>Hi all 
:>
:> Our shop is a monoplex configuration.We want to use a new OMVS couple 
dataset.
:>
:>1.We issue '-D XCF,COUPLE,TYPE=BPXMCDS' command.The following messages were 
shown:
:>
:>                       
:> IXC358I  16.07.47  DISPLAY XCF 850              
:> BPXMCDS COUPLE DATA SETS                        
:> PRIMARY    DSN: PLEXBDZ3.OMVS01.BK              
:>            VOLSER: BD3CD1     DEVN: 3F06        
:>            FORMAT TOD         MAXSYSTEM         
:>            12/27/2010 14:35:58        4         
:>            ADDITIONAL INFORMATION:              
:>              FORMAT DATA                        
:>               VERSION(2)                        
:>               MOUNTS(200)   AMTRULES(50)        
:> ALTERNATE  DSN: PLEXBDZ3.OMVS02.BK              
:>            VOLSER: BD3CD2     DEVN: 3C07        
:>            FORMAT TOD         MAXSYSTEM         
:>            12/27/2010 14:35:58        4         
:>            ADDITIONAL INFORMATION:              
:>               FORMAT DATA                         
:>                VERSION(2)                         
:>                MOUNTS(200)   AMTRULES(50)         
:>  BPXMCDS IN USE BY ALL SYSTEMS                    
:>
:>2. We define a new OMVS couple dataset( PLEXBDZ3.OMVS01) as the existing OMVS 
couple dataset.
:>
:>3. We issue 'SETXCF COUPLE,ACOUPLE=PLEXBDZ3.OMVS01' command.The following 
messages were shown   
:>                          
:> IXC309I SETXCF COUPLE,ACOUPLE REQUEST FOR SYSPLEX WAS ACCEPTED    
:> IXC260I ALTERNATE COUPLE DATA SET REQUEST FROM SYSTEM             
:> BDZ3 FOR SYSPLEX IS NOW BEING PROCESSED.                          
:> DATA SET:  PLEXBDZ3.OMVS01                                        
:> IXC255I UNABLE TO USE DATA SET                                    
:> PLEXBDZ3.OMVS01                                                   
:> AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN SYSTEM RECORDS     
:> IXC255I UNABLE TO USE DATA SET                                    
:> PLEXBDZ3.OMVS01                                                   
:> AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN RECOVERY RECORDS   
:> IXC255I UNABLE TO USE DATA SET                                    
:> PLEXBDZ3.OMVS01                                                   
:> AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN SYSPLEX RECORDS    
:> IXC255I UNABLE TO USE DATA SET                                    
:> PLEXBDZ3.OMVS01                                                   
:> AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN MEMBER RECORDS     
:>IXC260I ALTERNATE COUPLE DATA SET REQUEST FROM SYSTEM             
:>BDZ3 FOR SYSPLEX IS NOW BEING PROCESSED.                          
:>DATA SET:  PLEXBDZ3.OMVS01                                        
:>IXC255I UNABLE TO USE DATA SET                                    
:>PLEXBDZ3.OMVS01                                                   
:>AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN SYSTEM RECORDS     
:>IXC255I UNABLE TO USE DATA SET                                    
:>PLEXBDZ3.OMVS01                                                   
:>AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN RECOVERY RECORDS   
:>IXC255I UNABLE TO USE DATA SET                                    
:>PLEXBDZ3.OMVS01                                                   
:>AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN SYSPLEX RECORDS    
:>IXC255I UNABLE TO USE DATA SET                                    
:>PLEXBDZ3.OMVS01                                                   
:>AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN MEMBER RECORDS     
:>IXC255I UNABLE TO USE DATA SET                                    
:>PLEXBDZ3.OMVS01                                                   
:>AS THE ALTERNATE FOR SYSPLEX: DOES NOT CONTAIN IXCLKFLR RECORDS   
:>
:>Our questions:
:>
:>1.Could I issue '-SETXCF COUPLE,ACOUPLE=PLEXBDZ3.OMVS' in a monoplex 
configuration 
:>
:>2.Is there anything we didn't do?

--
Binyamin Dissen <[email protected]>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me,
you should preauthorize the dissensoftware.com domain.

I very rarely bother responding to challenge/response systems,
especially those from irresponsible companies.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to