Dear Bill
You are right.
I have other two questions:
1.Could you tell me why the records associated with the SYSPLEX couple data set
weren't in the incoming CDS ? Because of monplex configuration?
2. How to report on the contents of the BPXMCDS data?
Thanks a lot!
Best Regards,
Jason Cai
Re: Could I issue '-SETXCF COUPLE,ACOUPLE=PLEXBDZ3.OMVS' in a monoplex
configuration
As an earlier poster indicated, your ACOUPLE command must specify the TYPE
keyword:
SETXCF COUPLE,TYPE=BPXMCDS,ACOUPLE=PLEXBDZ3.OMVS01
Without it, the SETXCF command defaults to TYPE=SYSPLEX. Your original
ACOUPLE command failed because the system was expecting to find the records
associated with the SYSPLEX couple data set in the incoming CDS, and they
weren't there.
Your attempt to use IXCMIAPU to report on the contents of the BPXMCDS data
set failed because OMVS does not support use of the policy utility.
Bill Neiman
IBM Parallel Sysplex development
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html