Thanks to all who replied. The easiest would be if I could have used VLF/DLF
without having to write an application. I am changing the PDS to a PDSE. The
problem of going to VIO is that the jobs accessing the dataset run very
quickly with massive amounts of them (thousands) each hour. VIO would work
for long running jobs which these are not. Changing the format to a PDSE I'm
not sure where to expect to see the difference. I used GTF with SSCH to map
the SEEKA addresses and if the directory is cached I think I will see the
same number of SSCH SEEKA but they will be satisfied without going to the
device? Anyway to keep on topic DLF/VLF in this case were no help... Thanks
again... MXI rocks :)

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to