Daniel Allen pisze:
We have a XCF-local system with no access to a coupling facility. However, we 
would like to run CICS/TS 4.1 with DASD-only logging.

Can we create a COUPLExx parmlib member with LOGR only ?

Or do we need all five COUPLE facilities ?

No, and no.

You have to create two CDS types: sysplex (aka XCF) and LOGR.
Oh, BTW, there are 7 CDS types.


--
Radoslaw Skorupka
Lodz, Poland


--
BRE Bank SA
ul. Senatorska 18
00-950 Warszawa
www.brebank.pl

Sd Rejonowy dla m. st. Warszawy XII Wydzia Gospodarczy Krajowego Rejestru Sdowego, nr rejestru przedsibiorców KRS 0000025237
NIP: 526-021-50-88
Wedug stanu na dzie 16.07.2010 r. kapita zakadowy BRE Banku SA (w caoci wpacony) wynosi 168.248.328 zotych.
----------------------------------------------------------------------