Daniel Allen pisze:
We have a XCF-local system with no access to a coupling facility. However, we
would like to run CICS/TS 4.1 with DASD-only logging.
Can we create a COUPLExx parmlib member with LOGR only ?
Or do we need all five COUPLE facilities ?
No, and no.
You have to create two CDS types: sysplex (aka XCF) and LOGR.
Oh, BTW, there are 7 CDS types.
--