The term is in the z/OS 1.12 manual called 'Setting up a SYSPLEX'. IBM has not 
updated their information.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of 
Skip Robinson
Sent: Friday, February 25, 2011 10:02 AM
To: [email protected]
Subject: Re: Moving from XCF-local to single-system sysplex environment

Unless you are a running an ancient MVS release, 'XCF-Local' no longer exists. 
Single systems must now run as Monoplex. That being said, there is no problem 
running a system in Monoplex mode, which allows system logger to write to 
DASD-only data sets. 

Although it may not suit your needs, you can also run multiple systems in Basic 
Sysplex mode, which allows limited sharing of resources like console without 
any CF access. 


.
.
JO.Skip Robinson
SCE Infrastructure Technology Services
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[email protected]



From:   Daniel Allen <[email protected]>
To:     [email protected]
Date:   02/25/2011 08:31 AM
Subject:        Moving from XCF-local to single-system sysplex environment
Sent by:        IBM Mainframe Discussion List <[email protected]>



We have a XCF-local system with no access to a coupling facility. However, 
we would like to run CICS/TS 4.1 with DASD-only logging.

Can we create a COUPLExx parmlib member with LOGR only ?

Or do we need all five COUPLE facilities ?


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to