I have to change 1 system symbol for 1 sysres volume for 1 system in a 6 system sysplex. In my LOADXX member is it possible to override the IEASYM specification with an override at the system specfice level.
Example: IEASYM (00,Z0,L) NUCLST Z0 PARMLIB SYS1.LPLEX.PARMLIB PARMLIB SYS1.PARMLIB PARMLIB SYS1.IBM.PARMLIB SYSCAT CATL00133CCATALOG.LPLEX.MASTER SYSPARM (Z0) *-------------------------------------------------------------* * SL20 SPECIFIC VALUES * *-------------------------------------------------------------* LPARNAME SL20 IEASYM (01,Z0,L) IODF E0 SYS0 LPLEXFPB B0 Y SYSPARM (Z0,20) I have attempted this and did not get the desired result. I did not get an error on IPL but I received the concatenation in the first IEASYM statement. This leads me to believe I must have a seperate loadxx member for this system. Does anyone know a way around? ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html