On Fri, 3 Jun 2011 16:06:09 -0500, Rick Fochtman wrote: > >>//COND2 EXEC PGM=SETCOND,PARM=U111 >>// IF (COND2.RUN=TRUE OR COND2.ABENDCC=U0111) THEN >> >>//COND2 EXEC PGM=SSCOND,PARM=U111 >>// IF (COND2.RUN=TRUE OR COND2.ABENDCC=U0111) THEN >> >---------------------------------<unsnip>------------------------------------ >You keep using PARM= values in your examples. Try looking at the COND= >parameter of the EXEC statement. > What assumptions are you making about the specification of the SETCOND and SSCOND programs?
-- gil ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html