In a recent note, "Shmuel Metz (Seymour J.)" said:
> Date: Fri, 30 Dec 2005 12:32:54 -0500
>
> at 02:46 PM, Brian Peterson <[log in to unmask]> said:
>
> >What is really needed is a ++HOLD ACTION or ++HOLD EC with text
> >stating that "Vendor-A microcode level xxx is required for
> >compatability with PTF UZ11111". However, ++HOLD ACTION / ++HOLD EC
> >text must be included in the original PTF - they cannot be added
> >later.
>
> Are you sure they can't be picked up by RECEIVE HOLDDATA?
>
I believe the format is:
++HOLD SYSTEM REASON(ACTION) ...
(although:
++HOLD SYSTEM REASON(DEP) ... or
++HOLD SYSTEM REASON(EC) ...
might be more appropriate). And in:
Title: SMP/E V3R4.0 Reference
Document Number: SA22-7772-07
I see:
2.8 ++HOLD MCS
[ ... ]
SYSTEM
[ ... ]
System holds can appear in the SYSMOD itself or in a
separate HOLD input file.
-- gil
--