In a recent note, "Shmuel Metz (Seymour J.)" said:

> Date:         Fri, 30 Dec 2005 12:32:54 -0500
> 
>    at 02:46 PM, Brian Peterson <[log in to unmask]> said:
> 
> >What is really needed is a ++HOLD ACTION or ++HOLD EC with text
> >stating that "Vendor-A microcode level xxx is required for
> >compatability with PTF UZ11111".  However, ++HOLD ACTION / ++HOLD EC
> >text must be included in the original PTF - they cannot be added
> >later.
> 
> Are you sure they can't be picked up by RECEIVE HOLDDATA?
> 
I believe the format is:

    ++HOLD SYSTEM REASON(ACTION) ...

(although:

    ++HOLD SYSTEM REASON(DEP) ... or
    ++HOLD SYSTEM REASON(EC) ...

might be more appropriate).  And in:

    Title: SMP/E V3R4.0 Reference
    Document Number: SA22-7772-07

I see:

2.8 ++HOLD MCS
       [ ... ]
   SYSTEM
       [ ... ]
          System holds can appear in the SYSMOD itself or in a
          separate HOLD input file.

-- gil
-- 
StorageTek
INFORMATION made POWERFUL

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,