In a recent note, Staller, Allan said:

> Date:         Wed, 11 Jan 2006 08:25:08 -0600
> 
> I believe the above statement is incorrect.
> 
> SMP/E will receive anything in the SMPPTFIN file unless
> the SELECT(fmidset) operand is specefied. Ref. SMP/E Commands SC28-1805.
> SREL is another matter...
> 
I've long been accustomed to:

#2.2.498 "z/OS V1R1.0 SMP/E Messages, Codes, and Diagnosis"
     __________________________________________________________
        2.2.498 GIM38901I

   GIM38901I    aaaaaaaa PROCESSING FAILED FOR SYSMOD bbbbbbb
                BECAUSE IT HAS NO APPLICABLE ++VER MCS.

   Explanation:

     * aaaaaaaa -- an SMP/E command
     * bbbbbbb -- SYSMOD ID

   The indicated SYSMOD could not be processed because it does not
   have a ++VER MCS that names an SREL or an FMID defined in the
   GLOBALZONE entry.

   System Action: SMP/E does not receive the SYSMOD.

-- gil
-- 
StorageTek
INFORMATION made POWERFUL

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html