Lars, I would strongly recommend *against* doing this. What happens if they change their mind in the future and want to put it back?
In my opinion, a better idea would be to define SYSTEM-B to be part of the same SMSPLEX and HSMPLEX. Then *DISABLE* the storage group on SYSTEM-A and the associated HSM functions. Then fire up a second HSM on SYSTEM-B using the same ARCCMDxx member. You will need to look at the ONLYIF keyword to specify HSM functions to be performed only on SYSTEM-B. Unless there is something you haven't mentioned that prevents the above idea, I would re-think your plans for a second SMSPLEX. Bob Richards VP, Enterprise Technologist Enterprise Technology Infrastructure SunTrust Banks, Inc. (404) 575-2798 Seeing beyond money (sm) -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Lars Jansson Sent: Monday, January 16, 2006 10:55 AM To: [email protected] Subject: SMS LPAR We are running z/OS 1.4.0 and DFSMS 1.3.0 on "SYSTEM-A". Now we are planning to move a certain application to an own LPAR "SYSTEM-B" The application has it's own STORGRP and the plan is to start "SYSTEM-B" with a "mini SMS" that will contain the same STORGRP that the application has in "SYSTEM-A". If we need to migrate files with HSM we will send a batch job containing the HSM commands to "SYSTEM-A". Do you have any experience in this scenario ? LEGAL DISCLAIMER The information transmitted is intended solely for the individual or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination or other use of or taking action in reliance upon this information by persons or entities other than the intended recipient is prohibited. If you have received this email in error please contact the sender and delete the material from any computer. Seeing Beyond Money is a service mark of SunTrust Banks, Inc. [ST:XCL] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html