I believe he has managed to place a non-SMS dataset on an SMS managed
volume.  I wonder if the ADRDSSU CONVERTV command would fix him up.

Since it is a SMP/E SMPLTS file, he would be safe in deleting it and
allocate a new one.

On Wed, 18 Jan 2006 08:19:27 -0800, Ulrich Krueger <[EMAIL PROTECTED]>
wrote:

>Craig,
>take a look at IDCAMS DIAGNOSE and its options. That should give you some more
>information.
>Perhaps something like this, changed to your site's needs:
>//STEP1  EXEC  PGM=IDCAMS
>//SYSPRINT DD  SYSOUT=*
>//PRD88A   DD  UNIT=SYSDA,VOL=SER=PRD88A,DISP=SHR,
>//             DSN=SYS1.VVDS.VPRD88A,AMP='AMORG'
>//SYSIN    DD  *
>   DIAGNOSE VVDS -
>   COMPAREDS(ICFCAT.CVOLCATB) -
>   INFILE(PRD88A)
>
>But please don't ask me how to fix this ... if you can create a new dataset and
>copy the data, you ought to be good.
>This may be the time to call IBM.
>
>Regards,
>Ulrich Krueger
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,