On Tue, 14 Feb 2006 03:30:41 -0500, =?iso-8859-1?Q?Rugel_Jos=E9?=
<[EMAIL PROTECTED]> wrote:

>Hi:
>
>I  actually don't   remember  how  to make  Active  a  new  IOCDS  into
HMC,  can  anyone  give me  some  tips ?.
>
>Old  IOCDS  is  A2.
>New  IOCDS  must  be  A3,  but  how  I can  take  A3  as  an  Active
IOCDS ?.
>
If you have done some dynamic HCD work and have now written your IODF out
to IOCDS A3 and you want to ensure that the next time you initiate a Power-
On-Reset, you can issue the "ACTIVATE ACTIOCDS=A3" command from an MVS
console.

Hope this helps,
Roger

----------------------------------------------------------------------