Hi Bruce,

I tryed to INIT the target volume under MVS with INIT. But the copy always
fail.

My INIT :

ICKDSF - MVS/ESA    DEVICE SUPPORT FACILITIES 17.0                TIME: 0
                                                                         
 INIT UNIT(8801) VOLID(HI8801) VFY(HI8801)                               
ICK00700I DEVICE INFORMATION FOR 8801 IS CURRENTLY AS FOLLOWS:           
          PHYSICAL DEVICE = 3390                                         
          STORAGE CONTROLLER = 2105                                      
          STORAGE CONTROL DESCRIPTOR = E8                                
          DEVICE DESCRIPTOR = 0A                                         
          ADDITIONAL DEVICE INFORMATION = 4A000035                       
          TRKS/CYL = 15, # PRIMARY CYLS = 3339                           
ICK04000I DEVICE IS IN SIMPLEX STATE                                     
ICK00091I 8801 NED=  2105.   .HTC.55.000000011134                        
ICK31061I 8801 VTOC INDEX CREATION SUCCESSFUL: VOLUME IS IN INDEX FORMAT 
ICK01317I VTOC-INDEX IS LOCATED AT CCHH=X'0001 0000' AND IS    15 TRACKS.
ICK01314I VTOC IS LOCATED AT CCHH=X'0000 0001' AND IS    14 TRACKS.   
ICK00001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0 

My Copy :

PAGE 0001     5695-DF175  DFSMSDSS V1R3.0  DATA SET SERVICES     2006.083
09:29 
 COPY    TRACKS(0,0,3338,14)  COPYVOLID -

         ADMINISTRATOR PURGE -

         CPVOLUME -

         INDDNAME(ENTRADA) -

         OUTDDNAME(SAIDA)

ADR101I (R/I)-RI01 (01), TASKID 001 HAS BEEN ASSIGNED TO COMMAND 'COPY '

ADR109I (R/I)-RI01 (01), 2006.083 09:29:28 INITIAL SCAN OF USER CONTROL
STATEMEN
ADR016I (001)-PRIME(01), RACF LOGGING OPTION IN EFFECT FOR THIS TASK

ADR006I (001)-STEND(01), 2006.083 09:29:28 EXECUTION BEGINS

ADR307E (001)-OPNCL(11), UNABLE TO OPEN VOLUME HI8801, 16

ADR006I (001)-STEND(02), 2006.083 09:29:28 EXECUTION ENDS

ADR013I (001)-CLTSK(01), 2006.083 09:29:28 TASK COMPLETED WITH RETURN CODE
0008 
ADR012I (SCH)-DSSU (01), 2006.083 09:29:28 DFSMSDSS PROCESSING COMPLETE.
HIGHEST
                         TASK    001


But with INIT under VM

ICKDSF - CMS/XA/ESA DEVICE SUPPORT FACILITIES 17.0     
        03/24/06     PAGE   1                          
                                                       
ENTER INPUT COMMAND:                                   
  CPVOL FMT MODE(ESA) UNIT(8801) VOLID(HI8801) NOVFY - 
ENTER INPUT COMMAND:                                            
 RANGE(0,3338)                                                  
ICK00700I DEVICE INFORMATION FOR 8801 IS CURRENTLY AS FOLLOWS:  
          PHYSICAL DEVICE = 3390                                
          STORAGE CONTROLLER = 3990                             
          STORAGE CONTROL DESCRIPTOR = E9                       
          DEVICE DESCRIPTOR = 0A                                
          ADDITIONAL DEVICE INFORMATION = 4A001B35              
ICK04000I DEVICE IS IN SIMPLEX STATE                            
ICK00091I 8801 NED=  2105.   .HTC.55.000000011134               
ICK091I   8801 NED=  2105.   .HTC.55.000000011134               
ICK03020I CPVOL WILL PROCESS 8801 FOR VM/ESA MODE               
ICK03090I VOLUME SERIAL = HI8801                                
ICK03022I FORMATTING THE DEVICE WITHOUT FILLER RECORDS          
ICK03011I CYLINDER RANGE TO BE FORMATTED IS 0 - 3338            
ICK003D REPLY U TO ALTER VOLUME 8801 CONTENTS, ELSE T           
U                                                               
ICK03000I CPVOL REPORT FOR 8801 FOLLOWS:                        
                                                                
          FORMATTING OF CYLINDER 0 STARTED AT: 09:35:10         
          FORMATTING OF CYLINDER 100 ENDED AT: 09:35:13         
          FORMATTING OF CYLINDER 200 ENDED AT: 09:35:16 
          ...         
          FORMATTING OF CYLINDER 3338 ENDED AT: 09:37:03              
                                                                      
          VOLUME SERIAL NUMBER IS NOW = HI8801                        
                                                                      
          CYLINDER ALLOCATION CURRENTLY IS AS FOLLOWS:                
          TYPE     START      END        TOTAL                        
          ----     -----      ---        -----                        
          PERM     0          3338       3339                         
                                                                      
ICK00001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0            
          09:37:03    03/24/06                                        
                                                                      
ENTER INPUT COMMAND:         
end

Now the copy is OK 
 COPY    TRACKS(0,0,3338,14)  COPYVOLID -

         ADMINISTRATOR PURGE -

         CPVOLUME -

         INDDNAME(ENTRADA) -

         OUTDDNAME(SAIDA)

ADR101I (R/I)-RI01 (01), TASKID 001 HAS BEEN ASSIGNED TO COMMAND 'COPY '

ADR109I (R/I)-RI01 (01), 2006.083 09:40:02 INITIAL SCAN OF USER CONTROL
STATEME
ADR016I (001)-PRIME(01), RACF LOGGING OPTION IN EFFECT FOR THIS TASK

ADR006I (001)-STEND(01), 2006.083 09:40:02 EXECUTION BEGINS

ADR320I (001)-SBRTN(01), VOLUME SERIAL HI8801 ON UNIT 8801 IS CHANGED TO
L044B0
ADR344I (001)-SBRTN(01), VOLSER ON UCB 8801 IS A DUPLICATE. VOLUME MADE
UNAVAIL
ADR006I (001)-STEND(02), 2006.083 09:43:49 EXECUTION ENDS

ADR013I (001)-CLTSK(01), 2006.083 09:43:49 TASK COMPLETED WITH RETURN CODE
0000

I canĀ“t figure out what is the diference.