The problem was NCAL in the binder settings The subroutine LESERV require some LE modules from SCEEKLED to setup the runtime in order to display the LE-level and also the LE runtime options.
Roland -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Ed Micucci Sent: Wednesday, April 05, 2006 1:41 PM To: [email protected] Subject: Re: SHOWZOS v712 Roland, I failed to mention, the report output looks good in spite of the s0c1. Here's the symptom dump outputs, two s0c1's for each execution of SHOWZOS: SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001 TIME=07.24.27 SEQ=02652 CPU=0000 ASID=0031 PSW AT TIME OF ERROR 070C3000 80000002 ILC 2 INTC 01 NO ACTIVE MODULE FOUND NAME=UNKNOWN DATA AT PSW 00000000 - 000A0000 000130E1 00000000 GR 0: 00000000 1: 009AE0F0 2: 0A04FBB8 3: 00000000 4: 00FD3B20 5: 00FB1800 6: 00FB17D0 7: 00FB5640 8: 00FD32A0 9: 009E25A0 A: 7E85C194 B: 03DF102F C: 0A03D530 D: 009AE000 E: 8A04EF7A F: 00000000 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html