I do not really understand the question, but it sounds like the new system should have identical access to the channels, etc. I would research the Channel Path Access/Candidate Lists for any problems. You should be able to obtain a Channel Path Summary Report by selecting the following from the HCD panels: Print or compare configuration data, Print configuration reports, CSS report and CSS summary reports. Be aware devices can also have Candidate Lists.
Regards, Kevin -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Jimmy Wagner Sent: Friday, April 14, 2006 12:58 PM To: IBM-MAIN@BAMA.UA.EDU Subject: DASD Only Plex We have a 6 LPAR DASD only sysplex. We need to add a new LPAR to the configuration. Using existing CHP's, control units and devices were added for the new LPAR. A working unit was used as a model. The new devices connect to 5 of the 6 LPARs, 1 LPAR comes up as Path not operational. Does anyone have some insight as to what I need to look at? Thanks in advance. Jimmy ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html