I came up with 17 x 3390-27's (30051 Cyl). The ESS will let you know
exactly how many when you start to define them.
32 alias addresses for 17 -27 base addresses is too small for me. If you
don't have an addressing problem, you should define some more. Can you
define a new LCU for these -27 devices? That should get you around any
addressing shortages.

John

-- snip --
I have a 2105-F20 with 8 drawers of 18.2Gb disks. One of the current drawer
pair uses 256 devno's for base and alternate volumes,  the other 3 drawer
pairs uses only 128 of the addresses.  I know, lots of small volumes, but
we were migrating from MP3000 internal disk and an RVA that only supported
3390-3's when we got the 2105.  There are 8 ESCON channels to the box, no
FICON.

I'm adding 2 drawers of 72.8Gb drives.  I think I'll have to generate 16
base devices per drawer, allocate 15 3390-27's and have some a odd sizeed
16th device.  Does that sound correct?  I'll have 32 addresses for
alternates for each drawer.  (I have 6 38 address holes in the current
config).
-- snip --

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to