On Wed, 2006-05-17 at 14:07 -0500, McKown, John wrote: > I think it is so that when a job starts, that the > relative generation number always maps to the same absolute generation
The initiator maintains the "GDG name table" (I think that's it) which is a series of SWA control blocks queued off the JCT. Each control block has eyecatcher "GDGN" and holds up to three entries: a 35-byte GDG base name and a four-byte base generation number. "+0" refers to this base generation number throughout the job's execution. -- David Andrews A. Duda and Sons, Inc. [EMAIL PROTECTED] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html