Hi Francois.
You can do the following things:
A) VARY MYCONS01,CONSOLE
If the previous thing does not work ... Then
B) RESET CN(MYCONS01)
After of some seconds .. VARY MYCONS01,CONSOLE again
C) If the previous thing does not work ... Then
From some CONSOL active ... To assing the active console to Master
VARY MYCONS02,MSTCONS
Now from here....
VARY CN(MYCONS01),OFFLINE,FORCE
RESET CN(MYCONS01)
VARY MYCONS01,CONSOLE
Good Lucky
Atte.
Alvaro Quintupray B.
Ingeniero de Sistemas
Nexus S.A. Chile
Fon : 420 8149
-----Mensaje original-----
De: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] En nombre de
Francois Paré
Enviado el: Miércoles, 14 de Junio de 2006 11:26
Para: [email protected]
Asunto: Lost consoles
Hello,
We are using two OSA Integrated Console Controller to communicate with our
system consoles for our z890. We temporarily lost the network communication
between the two OSA interfaces and the two PCs that emulate the consoles so
we lost our two consoles. Is there a way to recover these consoles sessions
without doing an IPL?
Thank you very much.
************************************************************
Francois Pare
Universite Laval
Service de l'informatique et des telecommunications
Pavillon Casault
Ste-Foy (Quebec) Canada
G1K 7P4
tel.: 418-656-2131 ext. 4013
fax: 418-656-7305
************************************************************
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the
archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html