Hi Francois.

 You can do the following things:


A) VARY  MYCONS01,CONSOLE

        If the previous thing does not work ... Then

B) RESET CN(MYCONS01)

        After of some seconds ..  VARY MYCONS01,CONSOLE     again


C) If the previous thing does not work ... Then

    From some CONSOL  active ... To assing the active console to Master

    VARY  MYCONS02,MSTCONS

    Now from here....

    VARY  CN(MYCONS01),OFFLINE,FORCE

    RESET CN(MYCONS01)

    VARY  MYCONS01,CONSOLE


Good Lucky   


Atte.
Alvaro Quintupray B.
Ingeniero de Sistemas
  Nexus S.A. Chile
   Fon : 420 8149
 

-----Mensaje original-----
De: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] En nombre de
Francois Paré
Enviado el: Miércoles, 14 de Junio de 2006 11:26
Para: [email protected]
Asunto: Lost consoles

Hello,

 

We are using two OSA Integrated Console Controller to communicate with our
system consoles for our z890. We temporarily lost the network communication
between the two OSA interfaces and the two PCs that emulate the consoles so
we lost our two consoles. Is there a way to recover these consoles sessions
without doing an IPL?

 

Thank you very much. 

 

************************************************************

Francois Pare

Universite Laval

Service de l'informatique et des telecommunications

Pavillon Casault

Ste-Foy (Quebec) Canada

G1K 7P4

 

tel.: 418-656-2131 ext. 4013

fax: 418-656-7305

************************************************************

 

 


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the
archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to