In a message dated 7/2/2006 11:31:17 A.M. Central Standard Time,  
[EMAIL PROTECTED] writes:

If I  change the PAGE parameter with the new page dataset in IEASYS00 and it 
doesn't  work with the new ones how will I fix things if the LPAR doesn't come 
 up?

Isn't there any way to override this  parameter?  I thought that is how you 
override IEASYS00 parameters with  sysp= parameter.



>>
Fall back position? With new IEASYSxx ipl with R 00,clpa,sysp=xx
If that doesn't work go back to IEASYS00 with conventional
===> r 00,clpa
 
Lacking that have to go back to a restore  point? 

----------------------------------------------------------------------