I have read various posting about the problems of compressing a PDS
proclib. I have a proclib call TEST.PROCLIB which out of space.
Data Set Name . . . : TEST.PROCLIB
General Data Current Allocation
Volume serial . . . : D90300 Allocated tracks . : 1,478
Device type . . . . : 3390 Allocated extents . : 16
Organization . . . : PO Maximum dir. blocks : 250
Record format . . . : FB
Record length . . . : 80
Block size . . . . : 8880 Current Utilization
1st extent tracks . : 353 Used tracks . . . . : 1,478
Secondary tracks . : 75 Used extents . . . : 16
Used dir. blocks . : 192
Creation date . . . : 1996/12/17 Number of members . : 1,215
Referenced date . . : 2006/08/02
Expiration date . . : ***None***
TEST.PROCLIB is known to JES2 through the following PROC (JES2 on z/OS 1.4).
//JES2 PROC MEMBER=JES2PARM,ALTMEM=JES2PARM,
// PLIB2='SYS2.PROCLIB',PLIB3='TEST.PROCLIB'
//IEFPROC EXEC PGM=HASJES20,DPRTY=(15,15),TIME=1440,PERFORM=9
//ALTPARM DD DISP=SHR,DSN=SYS1.PARMLIB(&ALTMEM)
//HASPPARM DD DISP=SHR,DSN=SYS1.PARMLIB(&MEMBER)
//PROC00 DD DISP=SHR,DSN=SYS1.PROCLIB
// DD DSN=&PLIB2,DISP=SHR
// DD DSN=&PLIB3,DISP=SHR
// DD DISP=SHR,DSN=CPAC.PROCLIB
// DD DISP=SHR,DSN=IPO1.PROCLIB
// DD DISP=SHR,DSN=SYS1.IBM.PROCLIB
// DD DISP=SHR,DSN=IOE.SIOEPROC
//HASPLIST DD DDNAME=IEFRDER
How do I resolve this problem if it is not "safe" to compress?
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html