Hi All,
Is VTAM recycle required when the ISTMNPS structure is changed?
I understand from the Redbooks that its is not.
VTAM is supposed to automatically detect the changes.
If needed we could do 'V NET,CFS,ACTION=CONNECT,STRNAME=ISTMNPS'.
While VTAM started for the first time it had the following error:
IXL013I IXLCONN REQUEST FOR STRUCTURE ISTMNPS FAILED.
IST1365I FSNCN CONNECTION ATTEMPT TO STRUCTURE ISTMNPS FAILED
IST1366I FSNCN MVS MACRO IXLCONN FAILED - RTN CODE= 0C - REAS
IXLCONN RETURN CODE: 0000000C, REASON CODE: 02010C08
CONADIAG0: 00000002
CONADIAG1: 00000008
CONADIAG2: 00000C08
IXL015I STRUCTURE ALLOCATION INFORMATION FOR
STRUCTURE ISTMNPS, CONNECTOR NAME NETB_CDRMDOS
CFNAME ALLOCATION STATUS/FAILURE REASON
-------- ---------------------------------
ICF11 INVALID STRUCTURE SIZE
ICF21 INVALID STRUCTURE SIZE
I then increased the INITSIZE and SIZE.
In my environment a VTAM recycle(IPL) alone made VTAM aware of the ISTMNPS
structure change.
Regards,
Anu
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html