In respect of:

"ICH408I USER(CUPFNF1 ) GROUP(CICS    ) NAME(CICS REGION PROD    )  298
  PVOFNF.RM.RM.P140.RMHSTM.V CL(DATASET ) VOL(JAPSYS)                 
  INSUFFICIENT ACCESS AUTHORITY                                       
  FROM PVOFNF.** (G)                                                  
  ACCESS INTENT(ALTER  )  ACCESS ALLOWED(CONTROL)                     
IEC070I 211(8,17107)-221,CPSPFOR1,CPSPFOR1,RMHST01,5325,APOLXD,   "

It seems to me that the issue is NOT IEC070I but the preceding ICH408I which 
states that User CUPFNF1 has CONTROL authority over the data set in question 
but is trying to functions which require ALTER access.

The Security (RACF) administrator needs to be involved here I believe to ensure 
that correct access is grantted via the generic profile PVOFNF.**